1.2. Specification
Table 1.1. Technical data, AnaGate CAN quattro
Technical aspect Specfication
Desktop casing 155mm x 105mm x 40mm , fixable on DIN rail with optional
adapter kit
Measurements
Weight approx. 175g
Baud rate 10, 20, 50, 62.5, 100, 125, 250, 500, 800 or 1000 kbps,
software configuration
CAN controller 4x Microchip MCP 2515
CAN interface 4x ISO 11898-2 galvanic decoupled
CAN bus
Interface 4x pluggable clamp (4-pole) incl. CAN_H and CAN_L
Inputs 4, galvanic decoupled (3,3 – 24V)Digital IO
Outputs 4, galvanic decoupled, 3,3 – 24V (I
total max
= 0,5A)
Baud rate 10/100 Mbps
TCP/IP Static or dynamic (DHCP) IP address
LAN interface
Interface RJ45 socket
Voltage 9V-28V direct currentVoltage supply
Power consumption max. 350 mA (9V) without plugged USB consumers
Storage 0 .. 85 °CAmbient
temperature
In operation 0 .. 60 °C (industrial version: -20 .. 70°C)
Note
Protect the AnaGate CAN Gateway from direct sunlight.
1.3. Scope of delivery
The AnaGate CAN Gateway is supplied with the following components:
1x AnaGate CAN Gateway
1x CD with manual, programming API for Windows/Linux and CANopen driver for CANFestival
1x 1,8 m Cat. 5 LAN cable (standard, not crossed)
1x 10 pole Wago plug connector (for digital IO)
4x 4 pole plug connector for CAN interface
1x 2 pole Wago plug connector (for external power supply)
1 x plug-in power supply unit, compatible with country of delivery: EU, US or UK .