Chapter 3. Fields of application
If the AnaGate CAN Gateway is connected to the CAN bus, mind the following facts:
CAN_L: This line has to be connected to the CAN_Low line of the CAN bus.
CAN_H: This line has to be connected to the CAN_High line of the CAN bus.
GND: This line can be connected optionally to GND of the other bus devices.
3.1. Gateway mode
In gateway mode the CAN messages are transferred transparently over TCP/IP between the CAN network
and the host platform (e.g. PC) in both directions. The AnaGate CAN Gateway uses no unique CAN ID
when sending telegrams, this ID has to be set explicitly for each transmitted message.
All CAN messages received by the device are transmitted to all active LAN-connected host systems. It
is possible to discard all incoming messages in general or to set individual software filters to reduce the
message traffic to the host systems.
Figure 3.1. AnaGate CAN Gateway in gateway mode
The software program CAN Monitor, which is included on the documentation CD, can be used to
monitor a CAN bus or to create single CAN telegrams.
Application programs, which are using the included software API inteface.
Self-created batch files which are executed via the included LUA interpreter with integrated AnaGate
software API.