Analytica GmbH AnaGate CAN duo User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 25
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
5 © 2007-2010 Analytica GmbH
Chapter 2. Configuration
2.1. Initial installation
First the AnaGate CAN Gateway must be supplied via the power plug with a tension from 9 to 24 V.
Insert the included LAN cable into the plug labelled LAN and connect it either to a hub or switch. If
connecting to a PC use a crossover LAN cable (not in scope of delivery) instead of the included LAN cable.
The AnaGate CAN Gateway is delivered with the following initial network settings:
IP address 192.168.1.254
Address type static
Network mask 255.255.255.0
Gateway 192.168.1.1
The device can now be configured using a standard browser (Internet Explorer, Firefox, etc.) by using
http://192.168.1.254.
Figure 2.1. HTTP interface, AnaGate CAN uno
Note
The PC used for the configuration must be in the 192.168.1.x network. The static
IP address 192.168.1.2 with the subnet mask 255.255.255.0 can be e.g. used. If
neccessary the settings of the network interface on the configuration pc has to be changed
temporarily.