Configuration
8 © 2007-2014 Analytica GmbH
The inputs will be taken over immediately after clicking the button Save settings
and saved permanently on the AnaGate CAN Gateway . A restart of the device is not
necessary for activation of the settings.
Note
Maybe the ARP cache of the PC has to be deleted to find the device with
the changed IP address.
2.3. CAN settings
On the page CAN Settings the global settings for all existing CAN interfaces are
displayed and can be changed individually.
Figure 2.3. HTTP interface, CAN settings
Baudrate The baud rate can be selected easily via a list box
containing all supported values.
Termination Use the check box to switch on/off the internal
termination resistor.
High Speed Activates/deactivates the Highspeed mode. In this
operating mode all incoming/outgoing CAN telegrams
are not longer confirmed by the opposite LAN side to
accelerate process throughput. Software-Filters are
switched off too in this mode.
Boot with operational mode Initial operating mode of the CAN controller. Default
value is offline.